Kohler 12kW Air Cooled Standby Generator w/ 100-Amp 12-Circuit Load Center ATS | 12RESVL-100LC12

$4,728.00USD
Ex Tax: $4,728.00USD

Kohler 12kW Air Cooled Standby Generator w/ 100-Amp 12-Circuit Load Center ATS | 12RESVL-100LC12

The Kohler 12kW Generator 12RESVL-100LC12 is a complete Home Standby Generator Package with 100-Amp 12-Space Load Center Automatic Transfer Switch and Remote Generator Management System. When you lose power during an outage or blackout, the 12kW Kohler generator restores power fast to keep all your essential and critical loads up and working. The fridge and freezer stay cold, lights work, and pumps run when they should. The heat stays on in the winter and the AC runs in the summer. This generator and transfer switch will power most appliances in smaller home or a few critical items in larger homes. Restores power in as little as 10 seconds after an outage hits.

Power to start large loads without dropping power to other appliances. With a motor starting capacity of 20.3kVA, the Kohler 12RESV starts and runs a 5-Ton Air Conditioner in addition to a 5kW house load.

Exceptional digital voltage and frequency regulation for clean, smooth power with low harmonic distortion to protect sophisticated electronics.

Great for tight lot lines-18-inch to home installation distance.

Kohler's 725cc KT725 4-Cycle OHV engine handles tough applications. Runs on LP or NG and easily switches between the two in the field.

Kohler 12kW Generator Features

  • Reliable Commercial-Grade Engine Runs on Propane or Natural Gas
  • Powers Heat and Air Conditioning + Appliances and Electronics
  • Suitable for Home Standby or Off-Grid Applications
  • Built-In Mounting Pad Saves Installation Time & Money-No Need for Concrete
  • Simple Terminal Block for Easy Field Connections
  • Starts and Runs Heavy Loads-20.3kVA Motor Starting Capacity
  • Steel Enclosure with Automotive-Grade Paint for Advanced Corrosion Protection'

The RDC2 Controller integrates control for the generator set, RXT transfer switch, load management, and programmable interface module (PIM.) 

  • Membrane Keypad: OFF, AUTO, RUN Pushbuttons with Arrow and Select Buttons for Menus.
  • LED Indicators: OFF, AUTO, RUN Modes
  • LED Indicators: Utility Power, Generator Availability, Transfer Switch Position
  • LCD Display: 2 lines 16 Characters each with adjustable contrast for excellent visibility in all light conditions.

Kohler Premium 5-Year/2000-Hour Limited Warranty covers Parts, Labor, and Travel for the full warranty term.

*Requires a 12-Volt Group 51 Battery Rated for 500 Cold Cranking Amps.

Specifications

Model
Model Number : 12RESVL-100LC12
Transfer Switch Model : GM85273-SA6
Manufacturer : Kohler
Made In USA : Yes
Rated Watts : 12kW
Rated Watts Filter : 10 to 12.9 kW
Surge Watts : 20.3kVA
Rated Amps : 50 Amps
Voltage : 120/240 Volts Single Phase
Voltage Filter : 120/240 Volts
A/C Ton Rating : 5-Ton
Enclosure : Steel with E-Coat Corrosion Protection
UL Listed : UL-2200
Decibel Rating : 67 dB(A) Weekly Test | 71 dB(A) Full Speed
Type : Standby Generator
Transfer Switch Model : RXT 100 Amp 12 Space

Features
Starting System : Automatic Start
Low Oil Alert : Low Oil Shutdown
Mainline Breaker : 60 Amps
Battery Requirement : Requires 12V Group 51 500 CCA
Mounting Pad : Steel Base Attached
Weight : 433 Pounds
Dimensions : 30.6L x 28W x 32.4H inches

Warranty Information
Consumer Warranty : Kohler 5-Year/2000 Hour Limited Warranty

Engine
Engine Brand : Kohler KT725 4-Cycle
Engine Size : 725 cc OHV
Engine RPM : 3600
Cooling System : Air Cooled

Alternator
Alternator Type : 2-Pole Rotating Field 4-Lead
Frequency : 60 Hz
Auto Voltage Regulation : Yes

Fuel
Fuel Type : Natural Gas (NG) / Propane (LP)
Fuel Type Filter : Natural Gas or Propane
Fuel Gauge : No
NG Power Capacity : 11kW
LP Power Capacity : 12kW
NG Consumption @ Full Load : 216 Cubic-Feet per Hour
NG Consumption @ Half Load : 128 Cubic-Feet per Hour
LP Consumption @ Full Load : 2.6 Gallons per Hour
LP Consumption @ Half Load : 1.5 Gallons per Hour

Transfer Switches
Transfer Switch Amps : 100 Amps - Nema 1 Indoor Rated Only
Transfer Switch Circuits : 12 Space Load Center
Ats Poles : 2 Pole
Transfer Switch Weight : 20 Pounds
Quantity:
Genuine Products100% Original
Fast ShippingWorldwide
Easy Returns30-Day Policy
Expert Support24/7 Assistance

Product Description

Kohler 12kW Air Cooled Standby Generator w/ 100-Amp 12-Circuit Load Center ATS | 12RESVL-100LC12

The Kohler 12kW Generator 12RESVL-100LC12 is a complete Home Standby Generator Package with 100-Amp 12-Space Load Center Automatic Transfer Switch and Remote Generator Management System. When you lose power during an outage or blackout, the 12kW Kohler generator restores power fast to keep all your essential and critical loads up and working. The fridge and freezer stay cold, lights work, and pumps run when they should. The heat stays on in the winter and the AC runs in the summer. This generator and transfer switch will power most appliances in smaller home or a few critical items in larger homes. Restores power in as little as 10 seconds after an outage hits.

Power to start large loads without dropping power to other appliances. With a motor starting capacity of 20.3kVA, the Kohler 12RESV starts and runs a 5-Ton Air Conditioner in addition to a 5kW house load.

Exceptional digital voltage and frequency regulation for clean, smooth power with low harmonic distortion to protect sophisticated electronics.

Great for tight lot lines-18-inch to home installation distance.

Kohler's 725cc KT725 4-Cycle OHV engine handles tough applications. Runs on LP or NG and easily switches between the two in the field.

Kohler 12kW Generator Features

  • Reliable Commercial-Grade Engine Runs on Propane or Natural Gas
  • Powers Heat and Air Conditioning + Appliances and Electronics
  • Suitable for Home Standby or Off-Grid Applications
  • Built-In Mounting Pad Saves Installation Time & Money-No Need for Concrete
  • Simple Terminal Block for Easy Field Connections
  • Starts and Runs Heavy Loads-20.3kVA Motor Starting Capacity
  • Steel Enclosure with Automotive-Grade Paint for Advanced Corrosion Protection'

The RDC2 Controller integrates control for the generator set, RXT transfer switch, load management, and programmable interface module (PIM.) 

  • Membrane Keypad: OFF, AUTO, RUN Pushbuttons with Arrow and Select Buttons for Menus.
  • LED Indicators: OFF, AUTO, RUN Modes
  • LED Indicators: Utility Power, Generator Availability, Transfer Switch Position
  • LCD Display: 2 lines 16 Characters each with adjustable contrast for excellent visibility in all light conditions.

Kohler Premium 5-Year/2000-Hour Limited Warranty covers Parts, Labor, and Travel for the full warranty term.

*Requires a 12-Volt Group 51 Battery Rated for 500 Cold Cranking Amps.

Specifications

Model
Model Number : 12RESVL-100LC12
Transfer Switch Model : GM85273-SA6
Manufacturer : Kohler
Made In USA : Yes
Rated Watts : 12kW
Rated Watts Filter : 10 to 12.9 kW
Surge Watts : 20.3kVA
Rated Amps : 50 Amps
Voltage : 120/240 Volts Single Phase
Voltage Filter : 120/240 Volts
A/C Ton Rating : 5-Ton
Enclosure : Steel with E-Coat Corrosion Protection
UL Listed : UL-2200
Decibel Rating : 67 dB(A) Weekly Test | 71 dB(A) Full Speed
Type : Standby Generator
Transfer Switch Model : RXT 100 Amp 12 Space

Features
Starting System : Automatic Start
Low Oil Alert : Low Oil Shutdown
Mainline Breaker : 60 Amps
Battery Requirement : Requires 12V Group 51 500 CCA
Mounting Pad : Steel Base Attached
Weight : 433 Pounds
Dimensions : 30.6L x 28W x 32.4H inches

Warranty Information
Consumer Warranty : Kohler 5-Year/2000 Hour Limited Warranty

Engine
Engine Brand : Kohler KT725 4-Cycle
Engine Size : 725 cc OHV
Engine RPM : 3600
Cooling System : Air Cooled

Alternator
Alternator Type : 2-Pole Rotating Field 4-Lead
Frequency : 60 Hz
Auto Voltage Regulation : Yes

Fuel
Fuel Type : Natural Gas (NG) / Propane (LP)
Fuel Type Filter : Natural Gas or Propane
Fuel Gauge : No
NG Power Capacity : 11kW
LP Power Capacity : 12kW
NG Consumption @ Full Load : 216 Cubic-Feet per Hour
NG Consumption @ Half Load : 128 Cubic-Feet per Hour
LP Consumption @ Full Load : 2.6 Gallons per Hour
LP Consumption @ Half Load : 1.5 Gallons per Hour

Transfer Switches
Transfer Switch Amps : 100 Amps - Nema 1 Indoor Rated Only
Transfer Switch Circuits : 12 Space Load Center
Ats Poles : 2 Pole
Transfer Switch Weight : 20 Pounds